Ceska verze

Homemade X-ray photography

    Those pictures were made using the anode voltage of only 40kV and current 200uA, ie anode power only 8W. X-ray cassettes described in previous article were used, serving as a fluoroscope. First, cassete in its original condition was used (all photos except for the first two), then one of the screens was took out from the cartridge kodak. It seems that it is better when X-ray radiation does not pass cartridge body and goes directly on the screen :). In this way first 2 photos where photographed and the brightness is visibly better. The shielding effectiveness is carefully checked. The supply is remote controlled. The HV is set low to make the radiation easy to shield.


ionising x-ray radiation

    

WARNING!
This site doesn't serve as a guide! it is just a curiosity, not intended for reproduction. For this reason, I don't describe all safety precautions here. X-ray radiation is very dangerous ionizing radiation. Passes more or less through all materials, it cannot be completely shield. Exposure can cause cancer, leukemia, radiation sickness, tumours and other fatal diseases and infertility or mutation of offspring. The device operates with a very high voltage. Do not try this in any case ! If you, despite warnings, decided to implement it, I do not take any responsibility for your damage - everything you do at your own risk.


Screening Li-ion charger through the KODAK LANEX REGULAR screen gutted from the cartridge.
Screening Li-ion charger through the KODAK LANEX REGULAR screen gutted from the cartridge.

X-raying Li-ion charger


 Li-ion charger x-ray


Fluorescent tube starter
Fluorescent tube starter (screen still in the cassette)

Lighter x-ray
Lighter

USB-hub radiograph
USB-hub

electrolyte x-ray picture
electrolyte

laser pointer x-ray
laser pointer x-ray

Cable adapter cannon
Cable adapter

TV HV Multiplier TPN-11/10
TV HV Multiplier TPN-11/10

battery AA
battery AA

integrated circuit DIP40
integrated circuit DIP40

Energy saving fluorescent tube  x-ray
Energy saving fluorescent tube

switch
switch

all above x-rayed objects
all above x-rayed objects

meter
meter

USB from wireless mouse
USB from wireless mouse

relay roentgen
relay

camera from SE T300 cell phone
camera from SE T300 cell phone

4 above x-rayed objects
4 above x-rayed objects

Inside parts of 1W night light
Inside parts of 1W night light

PC CPU fan
PC CPU fan

fan and light x-ray
fan and light

X-ray system with large Chirana Tube and cassette AGFA with screen curix ortho regular 400
X-ray system with large Chirana Tube and cassette AGFA with screen curix ortho regular 400

I used camera Olympus MJU 1010, shutter 4s
Photographed using long shutter and 4s exposition.

Attachments cone X-ray tube on an insulating base
Attachments cone X-ray tube on an insulating base

Attachments cone X-ray tube on an insulating base
screw attaching

Attachments cone X-ray tube on an insulating base


Connected X-ray tube
Connected X-ray tube



Added: 2009
Previous
Next
home