Janis is right, Doctor! During the forward pulse, all of the current flows trough the upper diode and an energy accumulates in both capacitor and series inductor. After that, when the power is cut off, energy stored in inductor's core creates a current flow trough the lower diode, which continues charging the capacitor. Value of this current is only a fraction of initial current (one half if an optimal series inductance is chosen).